Small Solenoid Lock / Safety Door Switch [D4SL-N] (D4SL-N2RFG-DN)

Small Solenoid Lock / Safety Door Switch [D4SL-N] (D4SL-N2RFG-DN)
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      3,345₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

General-purpose enclosed switch with high shut-off capacity and high durability
[Features]
· ZE, ZV, and ZV2 types have built-in Z type general-purpose basic switch.
· Highly durable and has a large shutoff capacity.
· There are three types of mounting methods: side, bottom and side diagonal, as well as abundant actuator types.
· Connecting is easy since the terminal of the built-in switch is on the front when the cover is removed.
· Models with ground terminals support CE Marking.
· UL/CSA/CCC certified (contact the manufacturer for the certification format).

Dimensional Drawing of OMRON Limit Switch

D4SL-N□□□□-□N (connector type) of Limit Switch

Compact electromagnetic lock/safety door switch D4SL-N Model D4SL-N□□□□-□N (connector type) outline drawing

*If you insert a protruding part such as a pin into the φ4.5 hole and secure it in place, the installation will be more secure. 

D4SL-N□□□□-□ (Terminal block type) of Limit Switch

Compact electromagnetic lock/safety door switch D4SL-N Model D4SL-N□□□□-□(Terminal block type) Outline drawing

*If you insert a protruding part such as a pin into the φ4.5 hole and secure it in place, the installation will be more secure. 

Specification of OMRON Limit Switch

Performance of Limit Switch

Interlock TypeType 2 (EN ISO 14119)
Coding LevelLow level coded (EN ISO 14119)
Protective structure IP67 *1
TYPE 4X Indoor use only (UL, CSA)
Durability*2MechanicalOver 1 million times
ElectricalOver 150,000 times
(AC125V 1A resistive load)*3
Allowable Operating Speed0.05 to 1 m/s
Permitted operation frequency4, 5 contact type: 30 times/min
6 contact type: 5 times/min
Direct opening force*4Minimum 60N (EN60947-5-1)
Direct opening movement*4Minimum 15mm (EN60947-5-1)
Lock strength (Fzh)*5Minimum 1,300N
Contact Resistance200mΩ or less
Minimum applicable load*6DC5V 1mA resistive load (N level reference value)
Rated insulation voltage (Ui)150V (EN60947-5-1)
Rated Frequency50/60HZ
Electric shock protection classClass II (double insulated)
Pollution level (usage environment)Pollution degree 3 (EN60947-5-1)
Impulse
withstand voltage (Uimp)
(EN60947-5-1)
Between same-polarity terminals1.5kV
Between different terminals1.5kV
Between each terminal and non-current-carrying metal parts2.5kV
Insulation resistance100MΩ or more (at DC500V mega)
vibrationmalfunction10 to 55Hz, single amplitude 0.35mm
impactmalfunction80m/s2 or more
Durability1,000m/s2 or more
Conditional Short Circuit Current100A (EN60947-5-1)
Rated open thermal current (Ith)2.5A (11-42, 21-52, 21-22) 1A (other)
Ambient temperature-10 to +55℃ (but do not freeze)
Ambient humidity95% RH or less
massResin head
: approx. 290g (connector type)
, approx. 330g (terminal block type)
Metal head:
approx. 370g (connector type)
, approx. 410g (terminal block type)

Note 1. The above values ​​are initial values of Limit Switch.
   2. The switch contacts can be used for both normal and micro loads, but once a load has been opened or closed, a load with a smaller capacity cannot be connected to the contacts. Otherwise,
     the contact surface may become rough and the contact reliability may be impaired.
  *1. This protective structure is based on a test method based on the standard (EN60947-5-1), and the sealability under the actual usage environment and conditions should be confirmed in advance. 
     The switch box body is protected from the intrusion of dust and water, but the operation key insertion port in the head part should not be exposed to cutting chips, oil, water, chemicals, etc.
     This may cause early wear, damage, and failure.
  *2. The durability conditions are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH. Please contact us for other detailed conditions.
  *3. Do not apply AC125V 1A to three or more circuits.
  *4. Please ensure this for safe use.
  *5. Based on the evaluation method of ISO 14119.
  *6.This value may vary depending on switching frequency, environmental conditions, reliability level, etc. Please check with the actual load in advance.

Structure of Limit Switch

D4SL-N -D N connector type
D4SL-N -D Terminal block type
Compact Electromagnetic Lock/Safety Door Switch D4SL-N Model D4SL-N -D□N Connector Type Construction Diagram
Small Electromagnetic Lock/Safety Door Switch D4SL-N Model D4SL-N -D Terminal Block Type Construction Diagram

Specification Table of OMRON Limit Switch

D4SL-N□□□□-□N (connector type) of Limit Switch

D4SL-N□□□□-□ (Terminal block type) of Limit Switch

Operating CharacteristicsModel D4SL-N□□□-□□□N
Operation Key Insertion Force
Operation Key Withdrawal Force
Max 15N
Max 30N
Movement Until OperationMax 15mm
Movement Until Mechanical LockMin 3mm
Operating CharacteristicsModel D4SL-N□□□□-□
Operation Key Insertion Force
Operation Key Withdrawal Force
Max 15N
Max 30N
Movement Until OperationMax 15mm
Movement Until Mechanical LockMin 3mm
Part Number
D4SL-N2RFG-DN
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipDetector Shape Main Body Size Environment Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Cable Specifications Detector element details Indicator Light Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N·m)
Rubber material (scraper) Box shape Conduit size Specification of Terminal Mounting system Contact format Release key type Lock / release system Operating key insertion direction

₹ 9,511.17

1 Piece(s) 5 Day(s) [Others] KeySmallStandardTUV / UL / GB(CCC) / ENIP671515Mutual insulation double-throw1005DC125V13939155--24 VDC (Orange LED)-----G1/2Connector TypeMountable in Side Direction (Mountable on 4 Surfaces)3NC+3NCGeneral Key (Metal)Solenoid Lock / Mechanical Release ModelHorizontal Direction

Loading...

  1. 1

Basic Information

Operating Temperature Range(°C) -10::55

Please check the type/dimensions/specifications of the part D4SL-N2RFG-DN in the Small Solenoid Lock / Safety Door Switch [D4SL-N] series.

Product variants

Part Number
D4SL-N2AFG-N
D4SL-N2CFA
D4SL-N2CFA-N
D4SL-N2SFG
D4SL-N2VFA
D4SL-N2VFA-N
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetector Shape Main Body Size Environment Acquired Standards Protection Structure Force Required for Push Side O.F.
(N)
Motion to Switching P.T.
(mm)
Contact Type Mechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Rated Operating Voltage
(V)
Rated Conductance Current
(A)
Main Body External Dimension, Width W
(mm)
Main Body External Dimension, Height H
(mm)
Main Body External Dimension, Length L
(mm)
Cable Specifications Detector element details Indicator Light Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N·m)
Rubber material (scraper) Box shape Conduit size Specification of Terminal Mounting system Contact format Release key type Lock / release system Operating key insertion direction

₹ 8,113.57

1 Piece(s) 5 Day(s) -----------------Not Included--------1NC / 1NO + 1NC / 1NO (short circuit between door monitor and lock monitor)-Solenoid Lock / Mechanical Release Model-

₹ 8,799.17

1 Piece(s) 6 Day(s) -----------------Not Included--------2NC + 1NC / 1NO (Short circuit between door monitor and lock monitor)-Mechanical Lock / Solenoid Release Model-

₹ 8,113.57

1 Piece(s) 12 Day(s) -----------------Not Included--------2NC + 1NC / 1NO (Short circuit between door monitor and lock monitor)-Mechanical Lock / Solenoid Release Model-

₹ 8,845.50

1 Piece(s) 5 Day(s) [Others] KeySmallStandardEN / UL / GB(CCC) / TUVIP671515Mutual insulation double-throw1005DC125V13939179.9--Not Included-----G1/2Terminal Block TypeMountable in Side Direction (Mountable on 4 Surfaces)1NC / 1NO + 1NC / 1NO (no short circuit between door monitor and lock monitor)General Key (Metal)Solenoid Lock / Mechanical Release ModelHorizontal Direction

₹ 10,953.13

1 Piece(s) 5 Day(s) or more [Others] KeySmallStandardEN / UL / GB(CCC) / TUVIP671515Mutual insulation double-throw1005DC125V13939179.9--Not Included-----G1/2Terminal Block ModelSide Surface Direction Mounting (4-Directional Mountable)2NC + 2NC (no short circuit between door monitor and lock monitor)General Model Key (Metal)Mechanical Lock / Solenoid Release ModelHorizontal

₹ 10,102.75

1 Piece(s) 5 Day(s) or more [Others] KeySmallStandardEN / UL / GB(CCC) / TUVIP671515Mutual insulation double-throw1005DC125V13939179.9--Not Included-----G1/2Terminal Block ModelSide Surface Direction Mounting (4-Directional Mountable)2NC + 2NC (no short circuit between door monitor and lock monitor)General Model Key (Metal)Mechanical Lock / Solenoid Release ModelHorizontal
X
whatsapp-qr whatsapp-icon