Smart Sensor Built-in Amplifier CMOS Laser Sensor ZX1

Caution
- Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.
Product Description
CMOS laser sensor ideal for simple measurements.
[Features]
· Has resolution of 0.002 mm, used for simple measurements.
· Stable measurement in any sort of workpiece.
· Includes 4 types of variations in measurement depending on the distance without any installation constraints.
· Long-range type with sensing distance of 1,000 mm is also available.
Drawing
Model ZX1-LD50A61 (L) /A81 (L) /A66/A86, Model ZX1-LD100A61 (L) /A81 (L) /A66/A86

*For model ZX1-LD50□, L=50, A=21°
For model ZX1-LD100□, L=100, A=11.5°
Model ZX1-LD300A61 (L) /A81 (L) /A66/A86, Model ZX1-LD600A61 (L) /A81 (L) /A66/A86

*For model ZX1-LD300□, L=300, A=6.6°
For model ZX1-LD600□, L=600, A=3.4°
Product Specification
Performance
| Items | - | Part number | ||||
|---|---|---|---|---|---|---|
| NPN output | ZX1-LD50A61 ZX1-LD50A66 | ZX1-LD100A61 ZX1-LD100A66 | ZX1-LD300A61 ZX1-LD300A66 | ZX1-LD600A61 ZX1-LD600A66 | ||
| PNP output | Model ZX1-LD50A81 Model ZX1-LD50A86 | Model ZX1-LD100A81 Model ZX1-LD100A86 | Model ZX1-LD300A81 Model ZX1-LD300A86 | Model ZX1-LD600A81 Model ZX1-LD600A86 | ||
| Detection distance (distance center ± detection distance range) | 50 ± 10 mm | 100 ± 35 mm | 300 ± 150 mm | 600 ± 400 mm | ||
| Light source (emission wavelength) | Visible light semiconductor laser (660 nm, 1 mW or less, JIS Class 2, IEC/EN Class 2, FDA Class 2*1) | |||||
| Spot diameter (reference value) (defined at the center of the detection distance) *2 | ⌀0.17 mm | ⌀0.33 mm | ⌀0.52 mm | ⌀0.56 mm | ||
| Power supply voltage | 10 to 30 V DC (including 10% ripple (pp)) | |||||
| Power consumption | 2,500 mW or less (105 mA or less at 24 V, 210 mA or less at 12 V) | |||||
| Current Consumption | 250 mA or less (at power supply voltage 10 V DC) | |||||
| Control output | Load power supply voltage: 30 V DC or less, load current: 100 mA or less (residual voltage, 10 mA or less load current: 1 V or less, 10 to 100 mA load current: 2 V or less) | |||||
| Analog output | Current output: 4 to 20 mA, maximum load resistance 300 Ω (20 mA output at the nearest point and 4 mA output at the farthest point of the measurement range from the sensor) | |||||
| function | Smart tuning / keep function / scaling setting / background suppression function / Off-delay timer / on-delay timer / one shot timer / On-off delay timer / zero reset / area output / eco function / Hysteresis width setting / setting initialization | |||||
| Indicator Light | Digital display (red), output indicator light (OUT1, OUT2) (orange), zero reset indicator light (orange), menu indicator light (orange), laser illumination indicator light (green), smart tuning indicator light (blue) | |||||
| Response time | Judgment output | Fastest (SHS) mode: 1 ms High-speed (HS) mode: 10 ms, Standard (Stnd) mode: 100 ms | ||||
| Laser OFF input | 200 ms or less | |||||
| Zero reset input | 200 ms or less | |||||
| Temperature characteristics*3 | 0.03% F.S./°C | 0.04% F.S./°C | ||||
| Linearity*4 | +/- 0.15% F.S. | +/- 0.25% F.S. | +/- 0.25% F.S. (200–600 mm), +/- 0.5% F.S. (entire range) | |||
| Resolution *5 | 2 μm | 7 μm | 30 μm | 80 μm | ||
| Operating ambient illuminance | Light receiving surface illuminance, incandescent lamp: 7,500 lx or less | Light receiving surface illuminance, incandescent lamp: 5,000 lx or less | ||||
| Ambient temperature range | During operation: -10 to +55°C, during storage: -15 to +70°C (no freezing or condensation) | |||||
| Ambient humidity range | When operating/storing: 35 to 85% RH each (no condensation) | |||||
| Withstand voltage | 1,000 V AC 50/60 Hz for 1 min | |||||
| Vibration (endurance) | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z | |||||
| Shock (endurance) | 500 m/s2 in each X, Y, Z direction 3 times | |||||
| Protective structure*6 | IEC standard IP67 | |||||
| Connection method*7 | Pre-wired type (standard cord length: 2 m/5 m), inline connector type (standard cord length: 0.5 m) | |||||
| Weight (packaging state/main body only) | Pre-wired type (2 m) | approx. 240 g / approx. 180 g | approx. 270 g / approx. 210 g | |||
| Pre-wired type (5 m) | approx. 450 g / approx. 330 g | approx. 480 g / approx. 360 g | ||||
| Inline connector type (0.5 m) | approx. 170 g / approx. 110 g | approx. 200 g / approx. 140 g | ||||
| Material | Case / cover: polybutylene terephthalate, Optical window: glass, Cord: PVC, Installation hole section: SUS303 | |||||
| Accessory | Instruction manual, laser warning label (English) | |||||
Note 1. For objects with high reflectance, false detection may occur outside the measurement range.
*1. In accordance with FDA Laser Notice No. 50 and classified as Class 2 under IEC60825-1 standards, notification has been filed with the CDRH. (Accession Number: 1210041)
*2. Spot diameter: Defined as 1/e2 (13.5%) of the central light intensity at the center of the detection distance.
Light may leak outside the defined area, and if the reflectance of the area surrounding the workpiece is higher than that of the workpiece itself, it may affect the results.
Additionally, when detecting a workpiece smaller than the spot diameter, accurate measurement values may not be obtained.
*3. Temperature characteristics: These are the values when the sensor and the standard object are fixed in place using an aluminum jig. (Measured at the center of the detection distance)
*4. Linearity: Indicates the error relative to the ideal straight line of displacement output when measuring the standard object (white ceramic) at 25°C.
Linearity and measurement values may vary depending on the workpiece.
*5. Resolution: Defined when set to Standard (Stnd) mode and smart tuning is performed using the standard target (white ceramic).
This indicates the repeatability when the workpiece is stationary and does not indicate distance accuracy.
In strong electromagnetic fields, the performance of the resolution may not be satisfactory.
*6. When the connector part of the inline connector type is connected to an extension cable, it also achieves IP67 protection.
*7. Please use the inline connector type together with a 10 m or 20 m extension cable.