• MISUMI India HO Gurgaon & Pune regional office will be closed on 21st Oct, 2019 on account of assembly elections in Haryana & Maharashtra constituencies.

Stopper Bolt with Switch ST

Stopper Bolt with Switch ST

[Features]
1 unit dual roles. The stopper bolt has an in-built positioning switch.
· Reduction in the number of parts and design man-hour. Ensures miniaturization of the machinery
· Since the parts of th switch are cartridge type, the maintenance cost can be reduced drastically.
· Anybody can replace the switch easily.
· Eliminates the need for repairs.
· No damage is caused to the switch even if the chord gets twisted or pulled while fixing the switch into the machine and the operation can be performed easily.
· Improves the efficiency of the machine MTTR and the time required for "repairs" (for example: short-period stop) also reduces drastically.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
STE060PA
STE060PA-L
STE060PB
STE060PB-L
STE080PA
STE080PA-L
STE080PB
STE080PB-L
STE100PA
STE100PA-L
STE100PB
STE100PB-L
STP080DA
STP080DA-L
STP080DB
STP080DB-L
STP080UA
STP080UA-L
STP080UB
STP080UB-L
STP100DA
STP100DA-L
STP100DB
STP100DB-L
STP100UA
STP100UA-L
STP100UB
STP100UB-L
STS060PA
STS060PA-L
STS060PB
STS060PB-L
STS080PA
STS080PA-L
STS080PB
STS080PB-L
STS100PA
STS100PA-L
STS100PB
STS100PB-L
Part NumberVolume DiscountDays to ShipRoHSMain Body Shape Environment Contact Point Type Nominal of Thread (M) Operating Temperature Range
(°C)
Contact Force
(N)
Contact point accuracy life
(x 10K times)
Impact Resistant Energy
(J)
Protection Structure LED Specification details Operating point details
(mm)
6 Day(s) or more 10Hex head typeStandardContact type NOM6×1.00~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Hex head typeStandardContact type NOM6×1.00~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Hex head typeStandardContact type NCM6×1.00~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Hex head typeStandardContact type NCM6×1.00~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Hex head typeStandardContact type NOM8×1.250~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Hex head typeStandardContact type NOM8×1.250~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
12 Day(s) or more 10Hex head typeStandardContact type NCM8×1.250~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Hex head typeStandardContact type NCM8×1.250~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Hex head typeStandardContact type NOM10×1.50~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Hex head typeStandardContact type NOM10×1.50~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Hex head typeStandardContact type NCM10×1.50~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Hex head typeStandardContact type NCM10×1.50~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM8×1.250~80410000.4IP67NoFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM8×1.250~80410000.4IP67ProvidedFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM8×1.250~80410000.4IP67NoFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM8×1.250~80410000.4IP67ProvidedFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM8×1.250~80410000.4IP67NoFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM8×1.250~80410000.4IP67ProvidedFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM8×1.250~80410000.4IP67NoFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM8×1.250~80410000.4IP67ProvidedFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM10×1.50~80410000.4IP67NoFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM10×1.50~80410000.4IP67ProvidedFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM10×1.50~80410000.4IP67NoFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM10×1.50~80410000.4IP67ProvidedFor linear hit, water-proof type (downward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM10×1.50~80410000.4IP67NoFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeWaterproof TypeContact type NOM10×1.50~80410000.4IP67ProvidedFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM10×1.50~80410000.4IP67NoFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeWaterproof TypeContact type NCM10×1.50~80410000.4IP67ProvidedFor linear hit, water-proof type (upward boots protection included)(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM6×1.00~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM6×1.00~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NCM6×1.00~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NCM6×1.00~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM8×1.250~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM8×1.250~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeStandardContact type NCM8×1.250~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeStandardContact type NCM8×1.250~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM10×1.50~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
6 Day(s) or more 10Bolt TypeStandardContact type NOM10×1.50~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeStandardContact type NCM10×1.50~80210000.4IP65NoFor linear hit(From stopper surface) 0.3
10 Day(s) or more 10Bolt TypeStandardContact type NCM10×1.50~80210000.4IP65ProvidedFor linear hit(From stopper surface) 0.3

Loading...

  1. 1

Basic Information

Type Pin stroke shape/Spring Plungers Type / With Stopper Tip shape R Contact Body Material SUS303
Contact Material SUS HRC40~50 Stroke(mm) 0.7 Operating Point(mm) 0.3
Repeatability 0.01mm Allowable Static Load(N) 5000