(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
・ Compact size of 96 mm × 48 mm
・ With peak hold function
・ Up to 4 of 350 Ω strain gauge transducers can be connected
・ Protection rating: IP65
・ Wide power supply compatible (Front panel only with panel mount seal installed)
Bridge power supply | Within 10 VDC ± 0.5 V 60 mA (5 VDC, 2.5 VDC switching supported) | Input range | Supports F.S. setting at input of ±0.4 mV/V – ±3.1 mV/V (when bridge power supply is 10 VDC, 5 VDC); supports F.S. setting at input of ± 0.8 mV/V – ±3.1mV/V (when bridge power supply is 2.5 VDC) | Output range | ± 10 VDC, load resistance of 5 kΩ or greater (F.S. set via function) |
---|---|---|---|---|---|
Output resolution | Approx. 1/10,000 | Specification temperature humidity range | Temperature -10°C–50°C, humidity 85% RH or less | Power Supply Voltage | 100 VAC–240 VAC 50/60 Hz (allowable variable range: 85 VAC–264 VAC) |
External dimensions (W × H × D) | 96 mm×96 mm×129.5 mm | A D sampling | 2,000 times/s (100 times/s, 500 times/s, 1,000 times/s switching supported) | Nonlinearity | Display 0.025% F.S., output 0.025% F.S. |