Small Electromagnetic Lock Safety Door Switch [D4NL]

Caution
Product Description
One of the best seller of small size, multi-contact, and a variety of variations.
[Features]
· Direction of insertion port of operation key can be changed; various mounting patterns can be realized because of attachable double chamfer.
· Built-in switches are available in multi-contact types.
· Lock strength is 1,300 N or more.
· Compliant with both general load and micro load.
· M20 is added to conduit opening size.
· Multiple types of metallic heads available.
Drawing


*1. The dimensional tolerance for the parts not specified in the drawings of each model above is +/- 0.4 mm.
2. For contacts with 2 poles or more (2NC, 2NC/1NO, 3NC), there may be variations in the simultaneity of ON/OFF operation, so please check before use.
Product Specification
Structure

Performance
| Interlock type | Type 2 (EN ISO 14119) | |
|---|---|---|
| Encoding level | Low level coded (EN ISO 14119) | |
| Protective structure*1 | IP67 (EN60947-5-1) | |
| Durability*2 | Mechanical | More than 1 million times |
| Electrical | 500,000 operations or more (at 250 V AC 3 A resistive load) *3 | |
| Allowable operation speed | 0.05 to 0.5 m/s | |
| Allowable operation frequency | maximum 30 times/min | |
| Direct opening force*4 | Minimum 60 N (EN60947-5-1) | |
| Direct opening stroke*4 | Minimum 10 mm (EN60947-5-1) | |
| Lock strength (Fzh) *5 | Minimum 1,300 N | |
| Contact resistance | 25 mΩ or less (per contact) | |
| Minimum applicable load*6 | 5 V DC 1 mA resistive load (N-level reference value) | |
| Rated insulation voltage (Ui) | 300 V (EN60947-5-1) | |
| Rated frequency | 50/60 Hz | |
| Appliance Class | Class II (double insulation)![]() | |
| Pollution degree (operating environment) | Pollution degree 3 (EN60947-5-1) | |
| Impulse withstand voltage Uimp (EN60947-5-1) | Between terminals of the same polarity | 2.5 kV |
| Between different pole terminals | 4 kV | |
| Between each terminal and non-current-carrying metal part | 6 kV | |
| Insulation resistance | 100 MΩ or more (500 V DC insulation resistance tester) | |
| Contact gap | Minimum 2 x 2 mm | |
| Vibration | Malfunction | 10 to 55 Hz, Half amplitude 0.75 mm |
| Impact | Endurance | 1,000 m/s2 or more |
| Malfunction | 100 m/s2 or more | |
| Conditional short circuit current | 100 A (EN60947-5-1) | |
| Rated contact current (Ith) | 10 A (EN60947-5-1) | |
| Operating ambient temperature | -10 to 55℃ (no freezing) | |
| Operating ambient humidity | 95% RH or less | |
| Weight | Approx. 370 g (Model D4NL-1AFA-B) | |
*1. The values given above are initial values.
2. The switch contacts can be used for both general and micro loads; however, once a contact has switched a load, it cannot be used with a load of smaller capacity.
The surface of the contact may become rough, which could compromise contact reliability.
*1. This protective structure is based on test methods according to the standard (EN60947-5-1). Please confirm the sealing performance in advance under actual operating environment and usage conditions.
The switch box body is protected against the ingress of dust, water, and similar substances; however, please use it in a location where chips, water, chemicals, etc. will not come into contact with the operation key insertion slot on the head section.
This may cause premature wear, damage, or malfunction.
*2. The durability conditions are based on an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. Do not apply 250 V AC 3 A to more than two circuits.
*4. Please be sure to secure this to ensure safe use.
*5. According to the evaluation method of EN ISO14119.
*6. This value may vary depending on switching frequency, environmental conditions, and reliability level. Please check with the actual load in advance.