Loading...

Small Electromagnetic Lock Safety Door Switch [D4NL]

Brand :
OMRON

Caution

    Product Description

    One of the best seller of small size, multi-contact, and a variety of variations.
    [Features]
    · Direction of insertion port of operation key can be changed; various mounting patterns can be realized because of attachable double chamfer.
    · Built-in switches are available in multi-contact types.
    · Lock strength is 1,300 N or more.
    · Compliant with both general load and micro load.
    · M20 is added to conduit opening size.
    · Multiple types of metallic heads available.

    Drawing

    Compact safety door switch with electromagnetic lock D4NL External shape drawing-1
    Compact safety door switch with electromagnetic lock D4NL External shape drawing-2

    *1. The dimensional tolerance for the parts not specified in the drawings of each model above is +/- 0.4 mm.
       2. For contacts with 2 poles or more (2NC, 2NC/1NO, 3NC), there may be variations in the simultaneity of ON/OFF operation, so please check before use.

    Product Specification

    Structure

    Compact safety door switch with electromagnetic lock D4NL Structural drawing

    Performance

    Interlock typeType 2 (EN ISO 14119)
    Encoding levelLow level coded (EN ISO 14119)
    Protective structure*1IP67 (EN60947-5-1)
    Durability*2MechanicalMore than 1 million times
    Electrical500,000 operations or more (at 250 V AC 3 A resistive load) *3
    Allowable operation speed0.05 to 0.5 m/s
    Allowable operation frequencymaximum 30 times/min
    Direct opening force*4Minimum 60 N (EN60947-5-1)
    Direct opening stroke*4Minimum 10 mm (EN60947-5-1)
    Lock strength (Fzh) *5Minimum 1,300 N
    Contact resistance25 mΩ or less (per contact)
    Minimum applicable load*65 V DC 1 mA resistive load (N-level reference value)
    Rated insulation voltage (Ui)300 V (EN60947-5-1)
    Rated frequency50/60 Hz
    Appliance ClassClass II (double insulation)Compact Electromagnetic Lock / Safety Door Switch D4NL Electric Shock Protection Class Details
    Pollution degree (operating environment)Pollution degree 3 (EN60947-5-1)
    Impulse withstand voltage
    Uimp (EN60947-5-1)
    Between terminals of the same polarity2.5 kV
    Between different pole terminals4 kV
    Between each terminal and non-current-carrying metal part6 kV
    Insulation resistance100 MΩ or more (500 V DC insulation resistance tester)
    Contact gapMinimum 2 x 2 mm
    VibrationMalfunction10 to 55 Hz, Half amplitude 0.75 mm
    ImpactEndurance1,000 m/s2 or more
    Malfunction100 m/s2 or more
    Conditional short circuit current100 A (EN60947-5-1)
    Rated contact current (Ith)10 A (EN60947-5-1)
    Operating ambient temperature-10 to 55℃ (no freezing)
    Operating ambient humidity95% RH or less
    WeightApprox. 370 g (Model D4NL-1AFA-B)

    *1. The values given above are initial values.
    2. The switch contacts can be used for both general and micro loads; however, once a contact has switched a load, it cannot be used with a load of smaller capacity.
    The surface of the contact may become rough, which could compromise contact reliability.
    *1. This protective structure is based on test methods according to the standard (EN60947-5-1). Please confirm the sealing performance in advance under actual operating environment and usage conditions.
          The switch box body is protected against the ingress of dust, water, and similar substances; however, please use it in a location where chips, water, chemicals, etc. will not come into contact with the operation key insertion slot on the head section.
    This may cause premature wear, damage, or malfunction.
    *2. The durability conditions are based on an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
    *3. Do not apply 250 V AC 3 A to more than two circuits.
    *4. Please be sure to secure this to ensure safe use.
    *5. According to the evaluation method of EN ISO14119.
    *6. This value may vary depending on switching frequency, environmental conditions, and reliability level. Please check with the actual load in advance.