Loading...

Small Electromagnetic Lock Safety Door Switch [D4NL]

Brand :
OMRON

Caution

  • Product images are for reference only. Actual items may differ. Please refer to the product catalog for details.

Product Description

New at MISUMI? Get upto ₹10,000 Discount* on Your First Order. Click to Register Now

One of the best seller of small size, multi-contact, and a variety of variations.
[Features]
· Direction of insertion port of operation key can be changed; various mounting patterns can be realized because of attachable double chamfer.
· Built-in switches are available in multi-contact types.
· Lock strength is 1,300 N or more.
· Compliant with both general load and micro load.
· M20 is added to conduit opening size.
· Multiple types of metallic heads available.

Dimensional Drawing of OMRON Limit Switch

Small size electromagnetic lock safety door switch D4NL Outline drawing-1
Small Electromagnetic Lock/Safety Door Switch D4NL Outline Drawing-2

Note 1. Limit Switch, The dimensional tolerance of parts not specified in the above external dimension diagrams for each model is ±0.4 mm.
   2. There is variation in the simultaneity of the ON/OFF action of contacts with 2 or more poles (2NC, 2NC/1NO, 3NC), so please check before use.

Specification Table of OMRON Limit Switch

Structure of Limit Switch

Small electromagnetic lock/safety door switch D4NL structure diagram

Performance of Limit Switch

Interlock Type of Limit SwitchType 2 (EN ISO 14119)
Coding LevelLow level coded (EN ISO 14119)
Protective structure*1IP67 (EN60947-5-1)
Durability*2MechanicalOver 1 million times
Electrical500,000 times or more (AC250V 3A, with resistive load) *3
Allowable Operating Speed0.05 to 0.5 m/s
Permitted operation frequencyMaximum 30 times/min
Direct opening action*4Minimum 60N (EN60947-5-1)
Direct opening movement*4Minimum 10mm (EN60947-5-1)
Lock strength (Fzh) *5Minimum 1,300N
Contact Resistance25mΩ or less (per contact)
Minimum applicable load*6DC5V 1mA resistive load (N level reference value)
Rated insulation voltage (Ui)300V (EN60947-5-1)
Rated Frequency50/60Hz
Electric shock protection classClass II (double insulated)Small Electromagnetic Lock/Safety Door Switch D4NL Electric Shock Protection Class Contents
Pollution level (usage environment)Pollution degree 3 (EN60947-5-1)
Impulse withstand voltage
(Uimp) (EN60947-5-1)
Between same-polarity terminals2.5kV
Between different terminals4kV
Between each terminal and non-current-carrying metal parts6kV
Insulation resistance100MΩ or more (at DC500V mega)
Contact GapMinimum 2 x 2 mm
vibrationmalfunction10 to 55Hz, single amplitude 0.75mm
impactDurability1,000m/s2 ormore
malfunction100m/s2  ormore
Conditional Short Circuit Current100A (EN60947-5-1)
Rated open thermal current (Ith)10A (EN60947-5-1)
Ambient temperature-10 to +55℃ (but do not freeze)
Ambient humidity95% RH or less
massApprox. 370g (D4NL-1AFA-B)

Note 1. The above values ​​are initial values of Limit Switch.
   2. The switch contacts are compatible with both normal and micro loads, but once a load has been opened or closed, a load with a smaller capacity cannot be connected to the contacts. Otherwise,
      the contact surface may become rough and the contact reliability may be impaired.
*1. This protective structure is based on a test method based on the standard (EN60947-5-1), and the sealability under the actual usage environment and conditions should be confirmed in advance.
      The switch box body is protected from the intrusion of dust and water, but the operation key insertion port in the head part should not be exposed to cutting chips, water, chemicals, etc. This
      may cause early wear, damage, and failure of Limit Switch.
*2. The durability conditions are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH.
*3. Do not apply AC250V 3A to two or more circuits.
*4. Please ensure this for safe use.
*5. Based on the evaluation method of EN ISO14119.