Despite being an ultra compact proximity sensor, installation is surprisingly easy.
[Features]
· High-speed response frequency Max. 5 kHz enables stable detection of moving workpieces
· Equipped with four indicator lights, making alignment of the indicator light positions easy
·Dedicated installation metal fittings reduce labor-hours for jig fabrication
· Available with standard 5 m cable and robot (flexible) cable types

Drawing

Pre-Wired Type (shielded type)

Small diameter type proximity sensor E2E, pre-wired type (shielded type), drawing

M8 inline connector type (0.3 m) (shielded type)

Small diameter type proximity sensor E2E M8 inline connector type (0.3 m) (shielded type), drawing

M8 connector type (shielded type)

Small diameter type proximity sensor E2E M8 connector type (shielded type), drawing

Pre-Wired Type (shielded type)

Small diameter type proximity sensor E2E pre-wired type (non-shielded type), drawing

Product Specification

Rating / Performance

ItemsType
Model E2E-C03SR8*Model E2E-C03N02*Model E2E-C04S12*Model E2E-C04N03*Model E2E-C05S01*
Size⌀3⌀4⌀5.4
ShieldShieldNon-shieldedShieldNon-shieldedShield
Sensing distance (at 23°C)0.8 mm +/- 10%2 mm +/- 10%1.2 mm +/- 10%3 mm +/- 10%1 mm +/- 10%
Set distance *1
(detection distance x 0.7)
0 to 0.56 mm0 to 1.4 mm0 to 0.84 mm0 to 2.1 mm0 to 0.7 mm
Hysteresis15% or less of detection distance
Detectable objectsMagnetic metal (Detection distance is reduced for non-magnetic metals. See "Characteristic Data"
Standard detected objectSteel 3 x 3 x 1 mmSteel 6 x 6 x 1 mmSteel 4 x 4 x 1 mmSteel 9 x 9 x 1 mmSteel 5.4 x 5.4 x 1 mm
Response frequency *25 kHz3.5 kHz4 kHz2 kHz4 kHz
Power supply voltage
(same for working voltage range) *3
10 to 30 V DC, including 10% ripple (pp)
Current Consumption10 mA or less
Control output
*4
Contact CapacityOpen Collector 50 mA or lessOpen Collector 100 mA or less
Residual voltage2 V or less *5
Indicator LightOperation indicator: Yellow (compliant with European standard EN60947-5-2). Lights up during output.
Operating modeC1/C2: NPN type (negative common), B1/B2: PNP type (positive common)
C1/B1 type: NO (ON when approached), C2/B2 type: NC (ON when separated)
Protection circuitReverse power supply connection protection, surge absorption, load short-circuit protection, reverse output connection protection
Ambient temperature rangeWhen operating, when storing: -25 to +70°C each (no freezing or condensation)
Ambient humidity rangeWhen operating, when storing: 35 to 95% RH each (no condensation)
Effect of temperatureWithin +/-15% of the detection distance at +23°C within the temperature range of -25 to +70°C
Effect of voltageWithin +/-15% of the rated power supply voltage, within +/-2.5% of the sensing distance at the rated power supply voltage
Insulation resistance50 MΩ or more (500 V DC insulation resistance tester) between all live parts and the case
Withstand voltage500 V AC 50/60 Hz for 1 min between all live parts and the case
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude, 2 hr. in each direction of X, Y and Z
Shock (endurance)500 m/s2 in Each X, Y, Z Direction 10 times
Protective StructureIEC standard IP67, OMRON oil-resistant internal standard *6
Connection methodPre-Wired Typeavailableavailableavailable
M8 inline connector typeavailableavailableNot Included
M8 connector typeNot IncludedavailableNot Included
Weight
(packing
state)
Pre-Wired Typeapproximately 25 gApprox. 30 gApproximately 35 gApproximately 35 gApproximately 35 g
M8 inline connector typeApproximately 20 gApproximately 20 gapprox. 15 gApproximately 20 g-
M8 connector type--approx. 10 gapprox. 10 g-
MaterialCaseSUS303 (EN1.4305) *7Brass, nickel plating
Detecting surfaceHeat-resistant ABS
Tightening nut *8Not Included
Toothed washer *8Not Included
CordPVC
AccessoryInstruction manualavailable
Model Labelavailable
Mounting BracketSold separately
ItemsType
Model E2E-C06S02*Model E2E-C06N04*Model E2E-S04SR8*Model E2E-S04N02*Model E2E-S05S12*Model E2E-S05N03*
Sizeø 6.5M4M5
ShieldShieldNon-shieldedShieldNon-shieldedShieldNon-shielded
Sensing distance (at 23°C)2 mm +/- 10%4 mm +/- 10%0.8 mm +/- 10%2 mm +/- 10%1.2 mm +/- 10%3 mm +/- 10%
Set distance *1
(detection distance x 0.7)
0 to 1.4 mm0 to 2.8 mm0 to 0.56 mm0 to 1.4 mm0 to 0.84 mm0 to 2.1 mm
Hysteresis15% or less of detection distance
Detectable objectsMagnetic metal (Detection distance is reduced for non-magnetic metals. See "Characteristic Data"
Standard detected objectSteel sheet 6.5 x 6.5 x t1 mmSteel sheet 12 x 12 x t1 mmSteel 3 x 3 x 1 mmSteel 6 x 6 x 1 mmSteel 4 x 4 x 1 mmSteel 9 x 9 x 1 mm
Response frequency *23 kHz3 kHz5 kHz3.5 kHz4 kHz2 kHz
Power supply voltage
(same for working voltage range) *3
10 to 30 V DC, including 10% ripple (pp)
Current Consumption10 mA or less
Control output
*4
Contact CapacityOpen Collector
200 mA or less
(60 to 70°C: 100 mA)
Open Collector
50 mA or less
Open Collector
100 mA or less
Residual voltage2 V or less *5
Indicator LightOperation indicator: Yellow (compliant with European standard EN60947-5-2). Lights up during output.
Operating modeC1/C2: NPN type (negative common), B1/B2: PNP type (positive common)
C1/B1 type: NO (ON when approached), C2/B2 type: NC (ON when separated)
Protection circuitReverse power supply connection protection, surge absorption, load short-circuit protection, reverse output connection protection
Ambient temperature rangeWhen operating, when storing: -25 to +70°C each (no freezing or condensation)
Ambient humidity rangeWhen operating, when storing: 35 to 95% RH each (no condensation)
Effect of temperatureWithin +/-15% of the detection distance at +23°C within the temperature range of -25 to +70°C
Effect of voltageWithin +/-15% of the rated power supply voltage, within +/-2.5% of the sensing distance at the rated power supply voltage
Insulation resistance50 MΩ or more (500 V DC insulation resistance tester) between all live parts and the case
Withstand voltage500 V AC 50/60 Hz for 1 min between all live parts and the case
Vibration (endurance)10 to 55 Hz, 1.5 mm double amplitude, 2 hr. in each direction of X, Y and Z
Shock (endurance)500 m/s2 in Each X, Y, Z Direction 10 times
Protective StructureIEC standard IP67, OMRON oil-resistant internal standard *6
Connection methodPre-Wired Typeavailableavailableavailable
M8 inline connector typeavailableavailableavailable
M8 connector typeavailableNot Includedavailable
Weight
(packing
state)
Pre-Wired TypeApproximately 55 gApproximately 55 gApprox. 30 gApprox. 30 gApproximately 35 gApprox. 40 g
M8 inline connector typeApproximately 20 gapproximately 25 gApproximately 20 gApproximately 20 gApproximately 20 gApproximately 20 g
M8 connector typeapprox. 10 gapprox. 15 g--approx. 15 gapprox. 15 g
MaterialCaseSUS303 (EN1.4305) *7
Detecting surfaceHeat-resistant ABS
Tightening nut *8Not IncludedSUS430 (EN1.4016) *7
Toothed washer *8Not IncludedSUS303 (EN1.4305) *7
CordPVC
AccessoryInstruction manualavailable
Model Labelavailable
Mounting BracketSold separately

*1. By using the device within the specified distance, you can achieve high responsiveness and more stable repeatability.
* 2. The response frequency is an average value.
*3. Using a 12 V power supply makes the device less susceptible to the effects of internal self-heating, resulting in more stable repeatability.
*4. Keeping the control output at 20 mA or less makes the device less susceptible to the effects of internal self-heating, resulting in more stable repeatability.
*5. ⌀3, M4: when load current is 50 mA, cord length is 2 m
    ⌀4, ⌀5.4, M5: when load current is 100 mA, cord length is 2 m
    ⌀6.5: when load current is 200 mA, cord length is 2 m
*6. OMRON internal oil resistance standard: performance against non-water-soluble oil. (Test conditions are shown in the figure below)
*7. These are material names according to EN standards.
*8. Two tightening nuts and one toothed washer.

 

Oil resistance test conditions

After the test period, it has been confirmed that there are no issues with the following characteristics.
(1) External appearance (No damage that affects product characteristics)
(2) Operation check (ON/OFF)
(3) Insulation resistance (50 MΩ min., 500 V DC megger)
(4) Dielectric strength (500 V AC for 1 minute)
(5) Water resistance (IP67)
Small-diameter type proximity sensor E2E Oil Resistance Test Condition