  • The product images are representative only. Specifications may vary by part number, including shape and color.

Product Description

Compact limit switch excelling in compact size, thin and high seal properties.
[Features]
· Approved by EN (TÜV), UL, CSA, CCC standard. (ask your manufacturer for information on approved models)
· High sealing property compliant with IEC Standard IP67.
· The plunger has a seal packing, a diaphragm and the built-in switch has a protective cap and a triple seal structure.
· 3 m and 5 m cords are used as a standard. Series with cords certified by UL and CSA standards.
· Plunger type enables multiple mountings.
· A series of LED indicator lights (red) is made to facilitate confirmation during operation. (Lights up when not operating as a standard)
· VCTF oil-resistant cord type and pre-wired type products confirm with CE marking. (However this is applicable to the Standard type only)

Drawing

D4C-**01

Small limit switch D4C D4C-**01 drawing

Product Specification

Performance

Protective StructureIP67
Durability*1Mechanical*3More than 10 million times
Electrical*2More than 200,000 times (125 V AC 5 A resistant load)
Allowable operation speed0.1 mm to 0.5 m/s (for plunger type)
1 mm to 1 m/s (for roller lever type)
Allowable operation frequencyMechanical120 times/min
Electrical30 times/min
Rated frequency50/60 Hz
Insulation resistance100 MΩ or more (500 V DC insulation resistance tester)
Contact resistance (initial value)250 mΩ or less (with a 2 m cord)
300 mΩ or less (with a 3 m cord)
400 mΩ or less (with a 5 m cord)
Withstand voltageBetween terminals of the same polarity1,000 V AC 50/60 Hz for 1 min
Between current-carrying metal parts and ground1,500 V AC 50/60 Hz for 1 min
Uimp 2.5 kV (EN60947-5-1)
Between each terminal and non-current-carrying metal part1,500 V AC 50/60 Hz for 1 min
Uimp 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui)300 V (EN60947-5-1) *5
Pollution degree (operating environment)3 (EN60947-5-1)
Short circuit protection device10 A fuse gI or gG (IEC60269)
Conditional short circuit current100 A (EN60947-5-1)
Conventional enclosed thermal current (I the)5 A, 4 A, 0.5 A (EN60947-5-1)
Appliance ClassClass I (with ground wire) *6
VibrationMalfunction10 to 55 Hz double amplitude 1.5 mm *4
Impact resistantEnduranceMax. 1,000 m/s2
MalfunctionMax. 500 m/s2 *4
Operating ambient temperature-10 to +70℃ (no freezing)
Operating ambient humidity35 to 95% RH
Weight (D4C-1202)Approximately 360 g (with 3 m VCTF)
Approximately 540 g (with 5 m VCTF)

*The values given above are initial values.
* 1. The durability values are based on an ambient temperature of 5 to 35℃ and an ambient humidity of 40 to 70% RH, but durability varies depending on the type of load and magnitude of current.
*2. More than 1 million times for pre-wired type. (DC specification switching current 0.1 A)
* 3. More than 500,000 times for weather resistance type.
* 4.Excluding plastic rod type.
* 5. 250 V for pre-wired type.
* 6. class III for pre-wired type