All-metal & long distance type proximity sensor E2 V

Brand :
OMRON
Caution
Product Description
Long distance detection of both aluminum and iron.
[Features]
· Twice the aluminum detection distance compared to conventional models
· Equipped with a function that does not detect aluminum chips
· Visualization of detection achieved
· Recessed mounting in metal is possible
Drawing
Pre-Wired Type
Model E2 V-X2/X4
Model E2 V-X5/X8


Model E2 V-X10/X15

Inline connector type
Model E2 V-X4-M1TJ
Model E2 V-X8-M1TJ


Model E2 V-X15-M1TJ

Product Specification
Rating / Performance
| Size | Part number | ||||||
|---|---|---|---|---|---|---|---|
| M12 | M18 | M30 | |||||
| Items | Model E2 V-X2** | Model E2 V-X4** | Model E2 V-X5** | Model E2 V-X8** | Model E2 V-X10** | Model E2 V-X15** | |
| Sensing Distance | 2 mm +/- 10% | 4 mm +/- 10% | 5 mm +/- 10% | 8 mm +/- 10% | 10 mm +/- 10% | 15 mm +/- 10% | |
| Set distance | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 4.0 mm | 0 to 6.4 mm | 0 to 8.0 mm | 0 to 12.0 mm | |
| Hysteresis | 10% or less of detection distance | ||||||
| Detectable objects | Magnetic metals, non-magnetic metals (Sensing distance changes depending on material.) | ||||||
| Standard detected object | 12 x 12 x 3 (Aluminum) mm | 12 x 12 x 3 (Aluminum) mm | 18 x 18 x 3 (Aluminum) mm | 24 x 24 x 3 (Aluminum) mm | 30 x 30 x 3 (Aluminum) mm | 45 x 45 x 3 (Aluminum) mm | |
| Response frequency* | 150 Hz | 40 Hz | 70 Hz | 40 Hz | 70 Hz | 30 Hz | |
| Power supply voltage (operating voltage range) | 12 to 24 V DC, ripple (p-p) 10% or less (DC10 to 30 V) | ||||||
| Power consumption | 450 mW or less (15 mA or less current consumption at 30 V power supply voltage) | ||||||
| Control output | Contact Capacity | open collector output 100 mA or less | |||||
| Residual voltage | 2 V or less (when load current is 100 mA, cord length is 2 m) | ||||||
| Indicator light | NO type: operation indicator light (yellow) (blinking), setting indicator light (yellow) (lit), NC type: operation indicator light (yellow) (lit) | ||||||
| Operating mode | B1/C1 type: NO B2/C2 type: NC | ||||||
| Protection circuit | Power reverse connection protection, output reverse connection protection, load short-circuit protection, surge absorb | ||||||
| Ambient temperature range | When operating, when storing: -25 to +70°C each (no freezing or condensation) | ||||||
| Ambient humidity range | When operating, when storing: 35 to 95% RH each (no condensation) | ||||||
| Effect of temperature | Based on the detection distance at +23°C within the temperature range of -25 to +70°C | ||||||
| +/- 10% or less | +/- 15% or less | +/- 10% or less | +/- 15% or less | +/- 10% or less | +/- 15% or less | ||
| Effect of voltage | Within +/-15% of the rated power supply voltage, within +/-1.5% of the sensing distance at the rated power supply voltage | ||||||
| Insulation resistance | 50 MΩ or more (500 V DC insulation resistance tester) between all live parts and the case | ||||||
| Withstand voltage | 1,000 V AC 50/60 Hz for 1 min between all live parts and the case | ||||||
| Vibration (endurance) | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z | ||||||
| Shock (endurance) | 1,000 m/s2 in each X, Y, Z direction 10 times | ||||||
| Protective Structure | IEC standard IP67 (pre-wired type and inline connector type are OMRON internal oil-resistant standards) | ||||||
| Connection method | Pre-wired type (standard cord length: 2 m), connector type, inline connector type (standard cord length: 300 mm) | ||||||
| Weight (packing state) | Cord | Approx. 120 g | approx. 150 g | Approx. 200 g | |||
| Connector | Approx. 30 g | Approx. 45 g | Approx. 120 g | ||||
| Inline connector type | Approx. 50 g | Approximately 70 g | approx. 140 g | ||||
| Material | Case | Brass, nickel plating | |||||
| Detecting surface | Heat-resistant ABS | ||||||
| Mounting nut | Brass, nickel plating | ||||||
| Toothed washer | Iron, zinc plating | ||||||
| Accessory | Instruction manual | ||||||
*The response frequency is an average value.
The measurement conditions are to use the standard detected object, set the interval between the detected objects to twice that of the standard detected object, and set the distance to 1/2 of the sensing distance.