(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
· Proximity sensor with long thread length.
· To make cord protector a standard equipment, together with increasing the tightening strength.
· Increase the visibility of indicator lights and adopt for all models the milling cut for spanner grasping.
Proximity Sensors DC 2-wire type (E2E2-X□D□)
Proximity Sensors item | Proximity Sensors format | ||||||
---|---|---|---|---|---|---|---|
Model E2E2-X3D□ | Model E2E2-X8MD□ | Model E2E2-X7D□ | Model E2E2-X14MD□ | Model E2E2-X10D□ | Model E2E2-X20MD□ | ||
Proximity Sensors size | M12 | M18 | M30 | ||||
shield | shield | Unshielded | shield | Unshielded | shield | Unshielded | |
Detection distance | 3mm±10% | 8mm±10% | 7mm±10% | 14mm±10% | 10mm±10% | 20mm±10% | |
Set distance *1 | 0 to 2.4 mm | 0 to 6.4 mm | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
Hysteresis | 10% or less of the detection distance | ||||||
Detected object | Magnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data") | ||||||
Standard detection object | Iron 12 x 12 x 1 mm | Iron 30×30×1mm | Iron 18 x 18 x 1 mm | Iron 30×30×1mm | Iron 30×30×1mm | Iron 54×54×1mm | |
Response frequency *2 | 1kHz | 800Hz | 500Hz | 400Hz | 100Hz | ||
Power supply voltage (operating voltage range) | DC12-24V ripple (pp) 10% or less (DC10-30V) | ||||||
Leakage current | 0.8mA or less | ||||||
Control Output | Opening and closing capacity | 3 to 100mA | |||||
Residual voltage | 3V or less (load current 100mA, cord length 2m) | ||||||
Indicator Light | D1 type: Operation indicator (red), setting indicator (green) D2 type: Operation indicator (red) | ||||||
Operation mode (when detecting object approaching) | D1 type: NO, D2 type: NC For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8 | ||||||
Protection Circuit | Surge absorption, load short circuit protection | ||||||
Ambient temperature | During operation and storage: -25 to +70°C (but do not freeze or condense) | ||||||
Ambient Humidity | During operation and storage: 35 to 95% RH (but no condensation) | ||||||
Temperature effects | Within ±10% of detection distance at +23°C within the temperature range of -25 to +70°C | ||||||
Voltage Effects | Within ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage | ||||||
Insulation Resistance | 50MΩ or more (DC500V megger) between live parts and case | ||||||
Withstand voltage | AC1,000V 50/60Hz 1min Between live parts and case | ||||||
Vibration (durability) | 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions | ||||||
Impact (durability) | 1,000m/s2 10 times each in X, Y, and Z directions | ||||||
Protective structure | IEC standard IP67, Omron in-house standard oil resistance | ||||||
Connection method | Cord pull-out type (standard cord length 2m) | ||||||
Weight (packaged) | Approx. 65g | Approx. 150g | Approx. 210g | ||||
Proximity Sensors Material | case | brass | |||||
Detection surface | Polybutylene terephthalate (PBT) | ||||||
Clamping Nut | Brass, nickel plated | ||||||
Toothed washer | Iron, zinc plated | ||||||
accessories | operating instructions |
*1.The Proximity Sensors Use within the range where the green indicator light is on. (Excluding D2 type)
*2.The response frequency of the DC switching unit is the average value. The measurement conditions are as follows: The Proximity Sensors standard sensing object is used, the interval between sensing objects is twice that of the standardsensing object, and the set distance is 1/2 the sensing distance.
Proximity Sensors DC 3-wire type (E2E2-X□C□)
Proximity Sensors item | Proximity Sensors format | ||||||
---|---|---|---|---|---|---|---|
Model E2E2-X2C□ | Model E2E2-X5MC□ | Model E2E2-X5C□ | Model E2E2-X10MC□ | Model E2E2-X10C□ | Model E2E2-X18MC□ | ||
Proximity Sensors size | M12 | M18 | M30 | ||||
shield | shield | Unshielded | shield | Unshielded | shield | Unshielded | |
Detection distance | 2mm±10% | 5mm±10% | 5mm±10% | 10mm±10% | 10mm±10% | 18mm±10% | |
Set distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 4 mm | 0 to 8 mm | 0 to 8 mm | 0 to 14 mm | |
Hysteresis | 10% or less of the detection distance | ||||||
Detected object | Magnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data") | ||||||
Standard detection object | Iron 12 x 12 x 1 mm | Iron 15 x 15 x 1 mm | Iron 18 x 18 x 1 mm | Iron 30×30×1mm | Iron 30×30×1mm | Iron 54×54×1mm | |
Response frequency *1 | 1.5kHz | 400Hz | 600Hz | 200Hz | 400Hz | 100Hz | |
Power supply voltage (operating voltage range)*2 | DC12-24V ripple (pp) 10% or less (DC10-30V) | ||||||
Current consumption | 13mA or less | ||||||
Proximity Sensors Control Output | Opening and closing capacity | NPN open collector output 200mA or less (DC30V or less) | |||||
Residual voltage | 2V or less (load current 200mA, cord length 2m) | ||||||
Indicator Light | Operation indicator: (red) | ||||||
Proximity Sensors Operation mode (when detecting object approaching) | C1 type: NO, C2 type: NC For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8 | ||||||
Protection Circuit | Reverse connection protection, surge absorption, load short circuit protection | ||||||
Ambient temperature | During operation and storage: -40 to +85°C (but no freezing or condensation) | ||||||
Ambient Humidity | During operation and storage: 35 to 95% RH (but no condensation) | ||||||
Temperature effects | Within ±15% of detection distance at +23°C in a temperature range of -40 to +85°C Within ±10% of detection distance at +23°C in a temperature range of -25 to +70°C | ||||||
Voltage Effects | Within ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage | ||||||
Insulation Resistance | 50MΩ or more (DC500V megger) between live parts and case | ||||||
Withstand voltage | AC1,000V 50/60Hz 1min Between live parts and case | ||||||
Vibration (durability) | 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions | ||||||
Impact (durability) | 1,000m/s2 10 times each in X, Y, and Z directions | ||||||
Protective structure | IEC standard IP67, Omron in-house standard oil resistance | ||||||
Proximity Sensors Connection method | Cord pull-out type (standard cord length 2m) | ||||||
Weight (packaged) | Approx. 75g | Approx. 160g | Approx. 220g | ||||
Proximity Sensors Material | case | brass | |||||
Detection surface | Polybutylene terephthalate (PBT) | ||||||
Clamping Nut | Brass, nickel plated | ||||||
Toothed washer | Iron, zinc plated | ||||||
accessories | operating instructions |
*1.The response frequency of the DC switching unit is the average value. Measurement conditions are as follows: The Proximity Sensors standard detection object is used, the interval between detection objects is twice that of the standarddetection object, and the set distance is 1/2 the detection distance.
*2.The Proximity Sensors Can be used with a non-smooth full-wave rectified power supply of DC24V±20% (average value).
Proximity Sensors AC 2-wire type (E2E2-X□Y□)
Proximity Sensors item | Proximity Sensors format | ||||||
---|---|---|---|---|---|---|---|
Model E2E2-X2Y□ | Model E2E2-X5MY□ | Model E2E2-X5Y□ | Model E2E2-X10MY□ | Model E2E2-X10Y□ | Model E2E2-X18MY□ | ||
Proximity Sensors size | M12 | M18 | M30 | ||||
shield | shield | Unshielded | shield | Unshielded | shield | Unshielded | |
Detection distance | 2mm±10% | 5mm±10% | 5mm±10% | 10mm±10% | 10mm±10% | 18mm±10% | |
Set distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 4 mm | 0 to 8 mm | 0 to 8 mm | 0 to 14 mm | |
Hysteresis | 10% or less of the detection distance | ||||||
Detected object | Magnetic metals (non-magnetic metals will reduce the detection distance. See page 5 of the digital catalog for "Characteristics Data") | ||||||
Standard detection object | Iron 12 x 12 x 1 mm | Iron 15 x 15 x 1 mm | Iron 18 x 18 x 1 mm | Iron 30×30×1mm | Iron 30×30×1mm | Iron 54×54×1mm | |
Response Frequency | 25Hz | ||||||
Power supply voltage (operating voltage range) *1 | AC24~240V (AC20~264V) 50/60Hz | ||||||
Leakage current | 1.7mA or less | ||||||
Proximity Sensors Control Output | Opening and closing capacity *2 | 5 to 200mA | 5 to 300mA | ||||
Residual voltage | Characteristics data → See page 5 of the digital catalog | ||||||
Indicator Light | Operation indicator: (red) | ||||||
Operation mode (when detecting object approaching) | Y1 type: NO, Y2 type: NC For details, refer to the "Input/Output stage circuit diagram" time chart → Digital catalog page 8 | ||||||
Ambient temperature *1, 2 | During operation and storage: -40 to +85°C (but no freezing or condensation) | ||||||
Ambient Humidity | During operation and storage: 35 to 95% RH (but no condensation) | ||||||
Temperature effects | Within ±15% of detection distance at +23°C in a temperature range of -40 to +85°C Within ±10% of detection distance at +23°C in a temperature range of -25 to +70°C | ||||||
Voltage Effects | Within ±1% of detection distance at rated power supply voltage, within ±15% of rated power supply voltage | ||||||
Insulation Resistance | 50MΩ or more (DC500V megger) between live parts and case | ||||||
Withstand voltage | AC4,000V 50/60Hz 1min Between live parts and case | ||||||
Vibration (durability) | 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions | ||||||
Impact (durability) | 1,000m/s2 10 times each in X, Y, and Z directions | ||||||
Protective structure | IEC standard IP67, Omron in-house standard oil resistance | ||||||
Proximity Sensors Connection method | Cord pull-out type (standard cord length 2m) | ||||||
Weight (packaged) | Approx. 65g | Approx. 150g | Approx. 210g | ||||
Proximity Sensors Material | case | brass | |||||
Detection surface | Polybutylene terephthalate (PBT) | ||||||
Clamping Nut | Brass, nickel plated | ||||||
Toothed washer | Iron, zinc plated | ||||||
accessories | operating instructions |
*1.When Proximity Sensors using 24V AC, use within the ambient temperature range of -25 to +85°C.
*2.When using M18 and M30 types in ambient temperatures between 70°C and 85°C, use a control output (switching capacity) in the range of 5 to 200mA.
Part Number |
---|
E2E2-X2Y1 2M |
E2E2-X5Y1 2M |
E2E2-X10MY1 2M |
E2E2-X10Y1 2M |
E2E2-X18MY1 2M |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Detection distance L1 [classification] (mm) | Operating Environment | Shielded / Non-shielded | Screw Detection Head Size | Head size Depth (range) (mm) | Head size Depth (mm) | Acquired Standards | Types | Operation Mode | Connector pin arrangement | Cable Length (m) | Different Frequency Type | Cable Specifications | Included functions | Combination amplifier/head | Detection distance L1 details (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 7,739.00 | 1 Piece(s) | 5 Day(s) or more | ~2 | Standard / Oil Resistance Reinforcement / Cold Resistance | Shield Type | M12 | 50.1~60 | 55 | CE / IEC / CCC | Thread Length Long Size, AC, 2-Line | NO | - | 2 | Standard | Vinyl (PVC)-insulated round cord, φ4, 2-core/3-core | - | - | 2 | ||
₹ 7,186.40 | 1 Piece(s) | 5 Day(s) | ~5 | Standard / Oil Resistance Reinforcement / Cold Resistance | Shield Type | M18 | 50.1~60 | 60 | CE / IEC / CCC | Thread Length Long Size, AC, 2-Line | NO | - | 2 | Standard | Vinyl (PVC)-insulated round cord, φ6, 2-core/3-core | - | - | 5 | ||
₹ 9,226.27 | 1 Piece(s) | 5 Day(s) or more | ~10 | Standard / Oil Resistance Reinforcement / Cold Resistance | Non Shield Type | M18 | 50.1~60 | 60 | CE / IEC / CCC | Thread Length Long Size, AC, 2-Line | NO | - | 2 | Standard | Vinyl (PVC)-insulated round cord, φ6, 2-core/3-core | - | - | 10 | ||
₹ 10,069.00 | 1 Piece(s) | 5 Day(s) or more | ~10 | Standard / Oil Resistance Reinforcement / Cold Resistance | Shield Type | M30 | 60.1~70 | 65 | CE / IEC / CCC | Thread Length Long Size, AC, 2-Line | NO | - | 2 | Standard | Vinyl (PVC)-insulated round cord, φ6, 2-core/3-core | - | - | 10 | ||
₹ 10,103.00 | 1 Piece(s) | 5 Day(s) or more | ~20 | Standard / Oil Resistance Reinforcement / Cold Resistance | Non Shield Type | M30 | 60.1~70 | 65 | CE / IEC / CCC | Thread length long size, AC, 2-Line | NO | - | 2 | Standard | Vinyl (PVC)-insulated round cord, φ6, 2-core/3-core | - | - | 18 |
Loading...
Shape | Screw Type | Detected Objects | Magnetic Metal | Detection Direction | Front Surface |
---|---|---|---|---|---|
Case Material | Brass | Detecting Surface Material | Polybutylene Terephthalate | Amplifier | Amplifier Built-in Type |
Protection Structure (IEC) | IP67 | Power Type | AC, 2-Wire | Power Supply Voltage | 24-240 VAC |
Output Mode | AC, 2-Wire | Connection Method | Pre-wired model |