(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
● Polyethylene, more electrically stable than PVC, is used for insulation.
The Electrical Appliance and Material Safety Law certificate has not been obtained.
For Weak Current Circuit Signal / Instrumentation Cable
Model | Section Area (mm2) | Number of Pairs *1 1P = 2 Cores |
Total Length or Specified Length |
KNPEVSB | 0.2 | 1P | 1 ~ 100 (Specify 1 m Increment) |
2P | |||
3P | |||
5P | |||
10P | |||
0.3 | 1P | ||
2P | |||
3P | |||
5P | |||
10P | |||
0.5 | 1P | ||
2P | |||
3P | |||
5P | |||
10P |
Be sure to read the following precautions when you place an order.
* Length in "m" is included in our part numbers. Always specify quantity as number of units, not as meters.
*7 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of part number (m) x unit price per meter above]
Wire Core Identification Table
Pair No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
Insulator Color |
Core of Wire 1 |
Blue | Yellow | Green | Red | Purple | Blue | Yellow | Green | Red | Purple |
Core of Wire 2 |
White | White | White | White | White | Brown | Brown | Brown | Brown | Brown |
Specifications
Model | Section Area (mm2) |
Number of Pairs 1P = 2-Core *1 |
AWG Estimate* 2 |
Twisted Structure (See Figure) |
Number of Wire Cores |
Finished Outer Diameter (mm) |
Approximate Mass kg/km |
Electrical Properties | Conductor | Insulation | Wire Core Outer Diameter Approx. (mm) |
Sheath | Specification | Sample Provided |
|||||||
Allowable Current A (30°C) *3 |
Conductor Resistance Ω / km (20°C) |
Insulation Properties MΩkm (20°C) |
Withstand Voltage V / Min |
Structure Strands / mm |
Outer Diameter Approx. (mm) |
Plating *4 | Thickness (mm) |
Material *4 | Thickness (mm) |
Material *4 | |||||||||||
KNPEVSB | 0.2 | 1P | 24 | Twisted Pair | 2 | 5.5 | 35 | 5 | 112 or less | 5000 or more | AC500 | 7/0.18 | 0.54 | Tin | 0.25 | PE | 1.04 | 1.3 | PVC | N/A | — |
2P | 4 | 7.0 | 55 | 4 | — | ||||||||||||||||
3P | 6 | 7.5 | 60 | 3 | — | ||||||||||||||||
5P | 10 | 8.5 | 85 | 3 | — | ||||||||||||||||
10P | 20 | 10.0 | 115 | 2 | — | ||||||||||||||||
0.3 | 1P | 22 | 2 | 6.0 | 40 | 5 | 65.7 or less | 10,000 or more | AC700 | 12/0.18 | 0.72 | 0.3 | 1.32 | 1.3 | — | ||||||
2P | 4 | 8.0 | 70 | 5 | — | ||||||||||||||||
3P | 6 | 8.5 | 80 | 5 | — | ||||||||||||||||
5P | 10 | 10.0 | 115 | 4 | — | ||||||||||||||||
10P | 20 | 12.0 | 160 | 3 | — | ||||||||||||||||
0.5 | 1P | 20 | 2 | 7.0 | 55 | 5 | 39.4 or less | 10,000 or more | AC1000 | 20/0.18 | 0.93 | 0.4 | 1.73 | 1.3 | — | ||||||
2P | 4 | 9.5 | 100 | 5 | — | ||||||||||||||||
3P | 6 | 10.0 | 115 | 5 | — | ||||||||||||||||
5P | 10 | 12.0 | 160 | 5 | — | ||||||||||||||||
10P | 20 | 15.0 | 240 | 4 | — |
*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 Allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material; P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.
Current Reduction Factor
Ambient Temperature (°C) | 30 | 40 | 50 | 60 |
Current Reduction Factor | 1.00 | 0.88 | 0.74 | 0.57 |
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example)Allowable current value 5 x 0.88 = 4.4 (A) when the ambient temperature is 40°C at 1P 0.2mm2
Part Number |
---|
KNPEVSB-0.2-2P-[1-99/1] |
KNPEVSB-0.2-3P-[1-99/1] |
KNPEVSB-0.2-5P-[1-99/1] |
KNPEVSB-0.3-1P-[1-99/1] |
KNPEVSB-0.3-3P-[1-99/1] |
KNPEVSB-0.5-1P-[1-99/1] |
KNPEVSB-0.5-2P-[1-99/1] |
KNPEVSB-0.5-3P-[1-99/1] |
KNPEVSB-0.5-10P-[1-100/1] |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Overall Length (m) |
---|---|---|---|---|---|
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 99 | ||
- | 1 Piece(s) | 8 Day(s) or more | 1 ~ 100 |