(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...

SS30WS UL-Supported, Dual-Layer Shield (SS30WS-20P-100)

SS30WS UL-Supported, Dual-Layer Shield (SS30WS-20P-100)
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


● Noise countermeasures with braided shield & aluminum tape
● Diameter approximately 35% thinner than 300V model
Wiring is made easier.



· Not oil-resistant.
·
This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.


Product Description

- Power cable SS30WS UL-Supported, Dual-Layer Shield from MISUMI.
- 300 V double shielded cable, ULAWM20276 standard compliant, with excellent oil resistance and noise resistance.
- Only AWG size 28 is handled, and the use of twisted pair, braided shield, and aluminum tape provides excellent noise prevention.
- The diameter is approximately 35% thinner than 300V model.
- Color and softness may vary slightly due to manufacturer changes.
- The Insulation body materials are made of PVC.
- The insulation thickness of the power cable is 0.1 mm.

Specifications

SS30WS UL-Supported, Dual-Layer Shield:Related Image

Model NumberNumber of Pairs *4
1P = 2 Cores
Total Length *3
or
Specified Length
SS30WS5P1
~
100
(Specify 1 m
Increments)
·
500
·
1000
8P
10P
13P
17P
20P
25P
30P
32P
34P
50P


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings
(we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when
ordering.

More Information

SS30WS UL-Supported, Dual-Layer Shield:Related Image
SS30WS UL-Supported, Dual-Layer Shield:Related Image
SS30WS UL-Supported, Dual-Layer Shield:Related Image
Specifications
Model NumberPair No. *1
1P = 2-core
AWG
Size
Estimated
Section Area
(mm2) *2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished
Outer Diameter
(mm)
Approximate
Mass
kg / km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided
Allowable Current
A (30 °C) *3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩ km (20 °C)
Withstand Voltage
V / min
Structure
Pc / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
SS30WS5P280.08Twisted Pair105411240 or less10 or more3007/0.1270.38Tin0.1PVC0.58
± 0.02
0.81PVCULAWM
20276
8P165.5521246 or less
10P206.1591
13P266.5711
17P347.2851
20P407.61011.23
25P508.11131.14
30P6091391.04
32P6491481.04
34P6891600.93
50P10010.51800.93


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
 


Current Reduction Factor
Ambient Temperature (°C)3040506070
Current Reduction Factor1.000.890.770.630.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) AWG26: Allowable current value when the ambient temperature is 40 °C at 1P
2.2 x 0.89 = 1.958 (A)
SS30WS UL-Supported, Dual-Layer Shield:Related Image
SS30WS UL-Supported, Dual-Layer Shield:Related Image
Part Number
SS30WS-20P-100
Part NumberPriceMinimum Order Qty.Volume DiscountDays to Ship

₹ 31,398.33

1 Piece(s) 6 Day(s) or more

Loading...

  1. 1

Please check the type/dimensions/specifications of the part SS30WS-20P-100 in the SS30WS UL-Supported, Dual-Layer Shield series.

Product variants

Part Number
SS30WS-10P-100
SS30WS-13P-100
SS30WS-17P-100
SS30WS-25P-100
SS30WS-30P-100
SS30WS-32P-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

₹ 16,724.69

1 Piece(s) 6 Day(s) or more

₹ 20,149.04

1 Piece(s) 6 Day(s) or more

₹ 25,722.73

1 Piece(s) 6 Day(s) or more

₹ 37,927.62

1 Piece(s) 6 Day(s) or more

₹ 42,338.44

1 Piece(s) 6 Day(s) or more

₹ 54,068.65

1 Piece(s) 6 Day(s) or more