Loading...

Closed Loop Stepper Motors 86 Series

Brand :
MISUMI

Caution

    Product Description



    Product Overview
    Economy Series Closed-Loop Stepping Motors, 86 Series
     
    Dimensional Drawing
    ● Motor Dimensional Drawing
    Dimensional Drawing
    ● Driver Dimensional Drawing
    Driver Dimensional Drawing
    Specification Table
    Ordering Example
     
    Package ModelSeriesHolding Torque
    (N·m)
    Body Length
    L (mm)
    Rated Current
    (A)
    Resistance/Phase
    (Ω)
    Inductance/Phase
    (mH)
    Moment of Inertia
    (g.cm²)
    Power Voltage
    (V)
    SubdivisionEncoder Cable
    E-86ESTM01+EDR86A+3868126±260.613.62800VDC:
    24-80
    800-51200E-ECABLE3M (3m)
    E-86ESTM01+EDR86A+5E-ECABLE5M (5m)
    E-86ESTM02+EDR86A+312157±20.755.24300E-ECABLE3M (3m)
    E-86ESTM02+EDR86A+5E-ECABLE5M (5m)
    Product Features
    Product Features
    Precautions
    Note
    1. The driver and the motor are matched one-on-one, requiring no current setting.
    2. Stepping Motors, The subdivision can only adjust the smoothness of rotation, rather than increase the precision.
    3. The Stepping Motors needs to be used with the stepper driver, and cannot be directly connected to the power supply.
    4. The closed-loop Stepping Motors can be used only when the encoder wire is connected.
    5. The motor wiring must be performed in strict accordance with the drawing at the back of the motor.
    Example of Use
    Applications of the stepper motor in the medical industry
     
    Example of use of stepper motor
    Example of use of stepper motor