Loading...

Temperature Sensors Standard Screw Mount PT100 Type

Brand :
MISUMI

Caution

    Product Description



    Temperature Sensors Standard Screw Mount PT100 Type
    These Temperature Sensors type PT100 are an economy item, The price is cheaper than the MISUMI standard product.They offer a wide variety of sizes to choose from.
    [Feature]
    ● Temperature Sensors : Platinum Resistance Thermometers Type PT100
    ● Screw Size: M6 X 1.0
    ● Wire Length (m.): 1, 2, and 5
    ● Temperature Range (°C) : 0-200
    ● Crimp Terminal Type: Y-Shaped 3 sets
    [Application]
    It is used in a variety of application such as heat treatment, packaging industry , plastic industry , and so on.

    

    Economy Screw Mount Temperature Sensor

    Precise MeasurementDurable ConstructionSimple Integration

    - Provides accurate temperature readings within a specified range.

    - Built with a robust sheath to withstand harsh industrial environments, ensuring long-lasting operation.

    - Compatible with standard PT100 readout equipment, allowing for seamless integration into existing systems.

    - Thermocouple with various lead wire length options

    - Features a standard metric screw mount design for installation.

    Economy Screw Mount Temperature Sensor
    MISUMI Economy Logo

    MISUMI Standard
    MISUMI Standard

    Cheaper Price
    Cheaper Price

    Product Variety
    Product Variety

    3D CAD
    3D CAD Support


    Temperature Sensors Dimensional Drawing

    Dimensional Drawing
    For more information on product dimensional drawings, please refer to the Temperature Sensors product catalog.

    Temperature Sensors Specification Table

    Temperature Sensors TypeF(m)Screw SizeL(mm)ShapeTemperature Range
    C-MSNDPML61M6×1.065PT1000 to 200℃
    2
    5

    Temperature Sensors Product Overview

    Temperature Sensors, Thermocouple Sensor
    The thermocouple consists of two wires made of different materials, which are welded together at the end. After the ambient temperature of the unheated part is measured, the temperature of the heating point can be accurately known. Because it must have the conductor made of two different materials, it is called the thermocouple. The thermocouples made of different materials can be used in different temperature ranges, and their sensitivities are different from each other. The sensitivity of a thermocouple refers to the change in the output potential difference when the temperature of the heating point changes by 1°C. For most metal-supported thermocouples, this value is between 5-40 µV/°C.

    PT100
    Pt100 is a platinum thermal resistance, and its resistance value is proportional to the change of temperature. 100 after PT means that its resistance value is 100 ohms at 0°C and about 138.5 ohms at 100°C.

    Temperature Sensors Product Feature

    Genuine material and guaranteed wire diameter
    Fast temperature response
    More detailed improvements
    Various mounting head types

    Temperature Sensors Related Products

    Temperature Sensors Precautions

    Precautions
    Temperature Sensors PrecautionsPlease keep the upper limit of the temperature below the temperature measurement range of the product. If the bushing Temperature Sensors exceeds the heat-resistant temperature, it is very easy to cause the breakage of the temperature measurement wire.
    Temperature Sensors PrecautionsIf the temperature of heat generating parts exceeds 100°C, please choose the specification with a front end as long as possible.
     

    Temperature Sensors Usage Method

    Couples should not be installed too close to the door and heating place, and the insertion depth should be at least 8 to 10 times the diameter of the protection tube; the interval between the thermocouple protection bushing and the wall is not filled with insulation material, resulting in furnace heat overflow or cold air intrusion. Therefore, the interval between the thermocouple protection bushing and the furnace wall hole should be blocked with refractory mud or asbestos cord or other insulation materials so that the accuracy of temperature measurement will not be affected by hot and cold air convection; The cold end of the thermocouple is too close to the furnace, causing the temperature to rise above 100℃; thermocouples should be as far away as possible from strong magnetic and electric fields, so the thermocouples and power cable should not be installed in the same conduit to avoid deviation caused by interference; thermocouples can not be installed in the area where the measured medium rarely flow. Thermocouples must be installed against the direction of the flow and in full contact with the gas when the tube gas Temperature Sensors is measured by thermocouples.

    Temperature Sensors Brand introduction

    MISUMI, the head office company, has been providing customers with various high-quality parts such as automation parts, mold parts, electronic parts, tool & consumables, etc. quickly and accurately since its establishment in Japan in 1963. By compiling product catalogs independently and establishing a marketing system for direct sales of products, a low-cost business operation mode has been created, and by making annual product plans according to customers' opinions and requirements, MISUMI brand-name products with high quality level have been continuously developed
    Dimensional Drawing
    Dimensional Drawing
    For more information on product dimensional drawings, please refer to the product catalog.
    Specification Table
    TypeF(m)Screw SizeL(mm)ShapeTemperature Range
    C-MSNDPML61M6×1.065PT1000 to 200℃