Loading...

Air Volume Adjustable HEPA Filter Unit

Brand :
MISUMI

Caution

  • The power consumption of HEPAFS100-10-1 will be changed from February 2025 due to the specification change of the attached HEPA filter unit HEPAS100-10.
  • The change will be implemented sequentially as the stock runs out.
  • Please check the content on our website as the PDF does not contain the most up-to-date information.

Product Description

1 controller can adjust the air volume of 1 HEPA filter.

Dimensional Drawing of Air Conditioners, Air Holes

HEPAFS100-5-1 (HEPAS100-5 with airflow adjustment controller)
HEPAFS100-10-1 (HEPAS100-10 with airflow adjustment controller)

Air Conditioners, Air Holes
Air Conditioners, Air Holes ModelIncluded HEPA filter
unit
Air volume
m3/min
Mass
(kg)
External dimensionsCover HeightTop cover mounting pitchBottom air outlet sizeBottom mounting pitch
ABHG
Number of cover mounting bolts
JK1K2K3WVNumber of Tap
Holes
PQSY
HEPAFS100-5-1HEPAS100-5511.550050018550448375350-460470448375350-
HEPAFS100-10-1HEPAS100-101014.5610610659380225-57058059380450-

Specifications

Model
Air volume (air volume range)
HEPAFS100
10-1
・The Air Conditioners, Air Holes price list below is current as of April 2011.
・To check the latest price, please click the "Check Price" button after confirming the model number.
Air Conditioners, Air Holes Model
Airflow range
Included HEPA
Air volume m3 / min (controller volume) See diagram (A) above
Type
Single-phase power supply (V)
filter unit
HEPAF
S100
5-1
HEPAS100-5
5
4.2
3.9
3.3
2.9
1.6
1
0.5
0.5 or less
10-1
HEPAS100-10
10
9.3
7.7
6.1
3.9
2.3
1.1
1 or less
[ ! ]The airflow rate is an average value. Please adjust according to your environment.
■ Previous Model
 
Air Conditioners, Air Holes ModelHEPAFS100-5-1HEPAFS100-10-1
Included HEPA filter unitHEPAS100-5HEPAS100-10
Dust collection efficiency (atmospheric dust)
99.99% or more for 0.3μm particles
Main Filter
Air volume (m3/min)
5(5.0)
10(10)
Blowing speed (m/s)
0.39(0.39)
0.51(0.51)
Mass (kg)
11.5
14.5
Noise (dBA)
55(56)
56(57)
power supply100V specification
AC100V, 1φ, 50/60Hz,
5m power cord with installation plug included
Power consumption (W)100V specification
43(46)
98(114)
accessoriesPre-filter
Outlet packing: EDPM sponge

[ ! ] ( ) indicates 60Hz specification, noise was measured 1m from the outlet surface in an
anechoic chamber.

[ ! ] For an overview of HEPA/ULPA filter units, please click
■ Updated Model (To be replaced sequentially as stock runs out from February 2025)
The changes are indicated by * in the table below.
Air Conditioners, Air Holes ModelHEPAFS100-5-1HEPAFS100-10-1
Included HEPA filter unitHEPAS100-5HEPAS100-10
Dust collection efficiency (atmospheric dust)
99.99% or more for 0.3μm particles
Main Filter
Air volume (m3/min)
5(5.0)
10(10)
Blowing speed (m/s)
0.39(0.39)
0.51(0.51)
Mass (kg)
11.5
14.5
Noise (dBA)
55(56)
56(57)
power supply100V specification
AC100V, 1φ, 50/60Hz,
5m power cord with installation plug included
Power consumption (W)100V specification
43(46)
105(120)*
accessories
Pre-filter
Outlet packing: EDPM sponge

[ ! ] ( ) indicates 60Hz specification, noise was measured 1m from the outlet surface in an
anechoic chamber.

[ ! ]For an overview of HEPA/ULPA filter units, please click

How to Use Air Conditioners, Air Holes

HEPA filter unit with airflow adjustment function: Related images

Opening Dimensions of
Air Conditioners,
Air Holes
HEPA filter unit with airflow adjustment function: Related images

To install Air Conditioners, Air Holes on an aluminum frame unit, please prepare a mounting bracket with the opening shown on the right.
[!] Air Conditioners, Air Holes attach the included EPDM sponge between the mounting part and the unit.
* A 15mm screw is included. If the mounting part is 10mm thick or more, please prepare it separately.
HEPA filter unit with airflow adjustment function: Related images
HEPAFS and HEPAD have 10 levels of airflow adjustment.
Please refer to the specifications table of Air Conditioners, Air Holes for the airflow corresponding to each volume.